Video: OMRON F3SG Light Curtain Getting On Line and Factory Reset Using SD Manager2 Software


*** For more Product Informations visit http://industrial.omron.us/en/products/catalogue/safety/safetysensors/safety_light_curtain/f3sg_ra/default.html Going On Line, Uploading, Downloading And setting to Factory Default 1. Plug the F39-GIF into the receiver portion of the light curtain. 2. Plug the UBS portion into the USB of your PC. 3. Turn power off to the light curtain. 4. Set Dip Switch # 2 on both SW1 and SW2 to the ON position. Make sure not to set the dip switches with power ON. 5. Turn power on to the light curtain. 6. Open SD Manager 2 software. 7. If the driver is loaded correctly you should see a COM port in the upper left hand corner pull down. If not select the “Auto Scan” button the software will scan the USB ports to locate the plugged in cable. If the cable is found it should appear in the pulldown. 8. Select the “OK” button to go on line. 9. Select “Log In” button on the top of the window to bring up the Log In window. Verify that it is safe to put the light curtain in programming mode. 10. Select Administrator radio button and enter password. If no password has been entered previously or the unit is just opened from the factory the default password is 0000. Then select the “OK’ button to close the window. 11. If a previous program is loaded you would want to upload these settings to the attached PC. Select “Read Configuration” button. Setting the light curtain back to factory default: 1. Select the “Recovery” button to execute factory default procedure. To default the light curtain back to factory defaults, select the “Reset to Factory Default Settings” button. Verify the procedure was complete by looking at the bottom of the window and it should state “Tool success to recovery sensor setting”. 2. Select “Top page” button at the top of the window to go back to the main page. Downloading the program: 1. Select “Write Configuration” button. A write configuration window will appear. Anything in Yellow indicates it is changed from factory default. Verify the setting are correct and select the write button to download the settings. _____ Allen Bradley Banner Engineering Helm Instrument Co. Honeywell Sensing & Control HTM Electronic Industries Leuze Electronic Inc. Panasonic Electronic Works Pilz USA Pinnacle Systems Inc. Schmersal USA Schneider Electric Sick Inc. Smartscan Inc. Carlo Gavazzi Automation Direct Keyence Pepperl & Fuchs Wengler


Ver mas videos relacionados

Chatea con nosotros !