Video: OMRON F3SG Light Curtain Response Time Adjustment Using SD Manager2 Software


*** For more Product Informations visit http://industrial.omron.us/en/products/catalogue/safety/safetysensors/safety_light_curtain/f3sg_ra/default.html Response Time Adjustment using Software Tool 1. Set dip Switch # 8 of both SW1 and SW2 on the receiver to the ON position. 2. Go on line with the light curtain. 3. Set the light curtain to factory default. If you need help with this procedure review “F3SG-RA Getting On Line and Reset to Factory Demonstration Video Using SD Manager2 Software” video. 4. Select “Response Time Adjustment” button under the Function Setting area of the software. This will get you into the Response Time Adjustment window. 5. Select ether “Normal” or “Slow” radio button. 6. Select the “Write configuration” button to write the settings to the light curtain. This will bring up a write configuration window. To initiate the write select the “Write” button. Settings will then transfer to the light curtain. 7. To activate the light curtain you can go to the “Monitor “ button on the top of the page or cycle power to the unit. 8. Test the system by throwing something into the light curtain sensing field showing the effects of both the normal and slow response time. Allen Bradley Banner Engineering Helm Instrument Co. Honeywell Sensing & Control HTM Electronic Industries Leuze Electronic Inc. Panasonic Electronic Works Pilz USA Pinnacle Systems Inc. Schmersal USA Schneider Electric Sick Inc. Smartscan Inc. Carlo Gavazzi Automation Direct Keyence Pepperl & Fuchs Wengler